Any gaps in the list of drawings will be marked as either MISSING or DELETED. Missing drawings are simply ones I don't have, whereas deleted drawings were removed from the set by the drafting company or contractor. This latter group means that a drawing might exist, but was not part of the as-built set of final plans, or was later modified.

The Propellant Terminal blueprints are further broken down into the following sub-groups as shown in the following table and can be directly selected below to jump to those groups of drawings.

There are currently 33 drawings in the Propellant Terminal section.

NOTE: Drawing descriptions may be truncated and/or abbreviated to remove redundant text and maintain brevity in limited cell space.


Drawing Types

The following table provides quick selection of the types of drawings in the Propellant Terminal section. You can choose a category below, or scroll down to see everything in order.

At this time, there are only drawings available in the Architechtural, Details, Mechanical, Plumbing and Structural sub-categores for the Propellant Terminal category drawings. I hope more will be located and added in the future.

Sub-group Description
A Architectural
C Civil (NONE AVAILABLE)
CP Composite (NONE AVAILABLE)
D Details
E Electrical (NONE AVAILABLE)
M Mechanical
P Plumbing
S Structural

Propellant Terminal - Architechtural drawings (3)

Drawing Number Description
85-A-1 PLANS & FINISH SCHEDULE
85-A-2 MISSING *
85-A-3 SECTIONS
85-A-4 DETAILS

Propellant Terminal - Civil drawings (0)

Drawing Number Description
-- N/A

Propellant Terminal - Composite drawings (0)

Drawing Number Description
-- N/A

Propellant Terminal - Details drawings (4)

Drawing Number Description
85-D-1 SHOCK MOUNT ASS'Y. LIQUID OXYGEN STORAGE TANK
85-D-2 SHOCK MOUNT DETAILS LIQUID OXYGEN STORAGE TANK
85-D-3 MISSING *
85-D-4 MISSING *
85-D-5 MISSING *
85-D-5.1 PROPELLANT TERMINAL HORIZ. SHOCK MOUNTS
85-D-5.2 PROPELLANT TERMINAL VERT. SHOCK MOUNTS

Propellant Terminal - Electrical drawings (0)

Drawing Number Description
-- N/A

Propellant Terminal - Mechanical drawings (6)

Drawing Number Description
85-M-1 AIR CONDITIONING PLANS
85-M-1.1 AIR CONDITIONING PLANS
85-M-2 AIR CONDITIONING SECTIONS
85-M-3 AIR CONDITIONING DETAILS
85-M-4 AIR CONDITIONING PIPING & AIR FLOW DIAGRAMS
85-M-5 AIR CONDITIONING CONTROL DIAGRAMS

Propellant Terminal - Plumbing drawings (13)

Drawing Number Description
85-P-1 P.L.S. EQUIPMENT LOCATIONS SCHEDULE & PLANS
85-P-2 P.L.S. EQUIPMENT LOCATIONS PLANS & SECTIONS
85-P-3 MISSING *
85-P-4 P.L.S. PIPING PLAN UPPER LEVEL
85-P-5 MISSING *
85-P-6 P.L.S. PIPING PLAN LOWER LEVEL
85-P-7 P.L.S. PIPING PLAN SECTION A-A
85-P-8 P.L.S. PIPING PLAN SECTION B-B
85-P-9 P.L.S. PIPING SECTION MISC. - SHT. 1
85-P-10 P.L.S. INTERCONNECTING PIPING PLAN
85-P-11 P.L.S. INTERCONNECTING PIPING SECTIONS
85-P-12 P.L.S. HELIUM COOLER T-402 ___
85-P-13 P.L.S. LIQUID OXYGEN SUB-COOLER T-401
85-P-14 P.L.S. LIQUID OXYGEN STORAGE TANK T-201
85-P-15 P.L.S. PIPING SECTIONS - MISC. - SHT. 2

Propellant Terminal - Structural drawings (7)

Drawing Number Description
85-S-1 FOUNDATION PLAN & SECTIONS
85-S-2 FOUNDATION PLAN SPRING LAYOUT & DETAIL
85-S-3 SECTION
85-S-4 through 85-S-10 MISSING *
85-S-11 LIQUID OXYGEN TANK BAY PLAN & SECTIONS
85-S-12 LIQUID OXYGEN TANK BAY SECTIONS & DETAILS
85-S-13 LIQUID OXYGEN TANK BAY FOUNDATION & WALL PLAN
85-S-14 LIQUID OXYGEN TANK BAY FOUNDATION DETAILS
* Drawing is thought to be missing, meaning that it is thought to be in the index, but unavailable. This drawing's existence is only suggested by another drawing with a higher number. E.g., If a drawing such as 92-S-3 exists, it is reasonable to infer that 92-S-1 and 92-S-2 also likely exist. It is possible however, that some drawings which are expected to exist may have been deleted from the drawing index, so there is no certainty that these drawings actually exist, and so these entries should only be considered as placeholders.
Drawing title is woefully illegible and may not be accurate. Every effort has been made to discern the title's correct text, but some extrapolation, inference and outright guessing was required to arrive at a title for this drawing. In some cases a series of underscore characters ( ___ ) have been used to indicate the prescence of missing text that simply could not be positively identified.