More Info

Any gaps in the list of drawings will be marked as either MISSING or DELETED. Missing drawings are simply ones I don't have, whereas deleted drawings were removed from the set by the drafting company or contractor. This latter group means that a drawing might exist, but was not part of the as-built set of final plans, or was later modified.

The Propellent Terminal blueprints are further broken down into the following sub-groups as shown in the following table and can be directly selected below to jump to those groups of drawings.

At this time, there are no drawings available in the following sub-groups: Composite, HVAC, and Plumbing.

There are currently 15 drawings in the Propellent Terminal section.

NOTE: Drawing descriptions may be truncated and/or abbreviated to remove redundant text and maintain brevity in limited cell space.


Drawing Types

The following table provides quick selection of the types of drawings in the Propellent Terminal section. You can choose a category below, or scroll down to see everything in order.

Sub-group Description
A Architectural
CP Composite (NONE AVAILABLE)
D Details
E Electrical
H HVAC (NONE AVAILABLE)
M Mechanical
P Piping
PL Plumbing(NONE AVAILABLE)
S Structural

Propellent Terminal - Architectural drawings (2)

Drawing Number Description
95-A-1 PLANS & FINISH SCHEDULE
95-A-2 MISSING *
95-A-3 MISSING *
95-A-4 DETAILS
* Drawing is thought to be missing, meaning that it is thought to be in the index, but unavailable. This drawing's existence is only suggested by another drawing with a higher number. E.g., If a drawing such as 92-S-3 exists, it is reasonable to infer that 92-S-1 and 92-S-2 also likely exist. It is possible however, that some drawings which are expected to exist may have been deleted from the drawing index, so there is no certainty that these drawings actually exist, and so these entries should only be considered as placeholders.

Propellent Terminal - Composite drawings (0)

Drawing Number Description
-- N/A

Propellent Terminal - Details drawings (1)

Drawing Number Description
95-D-1 MISSING *
95-D-2 MISSING *
95-D-3 MISSING *
95-D-4 FIRE DOOR FRAMING
* Drawing is thought to be missing, meaning that it is thought to be in the index, but unavailable. This drawing's existence is only suggested by another drawing with a higher number. E.g., If a drawing such as 92-S-3 exists, it is reasonable to infer that 92-S-1 and 92-S-2 also likely exist. It is possible however, that some drawings which are expected to exist may have been deleted from the drawing index, so there is no certainty that these drawings actually exist, and so these entries should only be considered as placeholders.

Propellent Terminal - Electrical drawings (1)

Drawing Number Description
95-E-1 MISSING *
95-E-2 MISSING *
95-E-3 MISSING *
95-E-4 MISSING *
95-E-5 MISSING *
95-E-6 BONDING & GROUNDING PLAN
* Drawing is thought to be missing, meaning that it is thought to be in the index, but unavailable. This drawing's existence is only suggested by another drawing with a higher number. E.g., If a drawing such as 92-S-3 exists, it is reasonable to infer that 92-S-1 and 92-S-2 also likely exist. It is possible however, that some drawings which are expected to exist may have been deleted from the drawing index, so there is no certainty that these drawings actually exist, and so these entries should only be considered as placeholders.

Propellent Terminal - HVAC drawings (0)

Drawing Number Description
-- N/A

Propellent Terminal - Mechanical drawings (2)

Drawing Number Description
95-M-1 AIR CONDITIONING PLANS
95-M-2 AIR CONDITIONING SECTIONS

Propellent Terminal - Piping drawings (2)

Drawing Number Description
95-P-1 MISSING *
95-P-2 MISSING *
95-P-3 MISSING *
95-P-4 MISSING *
95-P-5 MISSING *
95-P-6 MISSING *
95-P-7 MISSING *
95-P-8 MISSING *
95-P-9 P.L.S. TYPE "D" TUNNEL PIPING PLAN
95-P-10 MISSING *
95-P-11 P.L.S. TYPE "D" TUNNEL PIPING SECTIONS
* Drawing is thought to be missing, meaning that it is thought to be in the index, but unavailable. This drawing's existence is only suggested by another drawing with a higher number. E.g., If a drawing such as 92-S-3 exists, it is reasonable to infer that 92-S-1 and 92-S-2 also likely exist. It is possible however, that some drawings which are expected to exist may have been deleted from the drawing index, so there is no certainty that these drawings actually exist, and so these entries should only be considered as placeholders.

Equipment Terminal - Plumbing drawings (0)

Drawing Number Description
-- N/A

Propellent Terminal - Structural drawings (7)

Drawing Number Description
95-S-1 FOUNDATION PLAN & SECTION
95-S-2 MISSING *
95-S-3 SECTION
95-S-4 WALL OPENINGS ORIENTATION & ELEVATIONS
95-S-5 MISSING *
95-S-6 MISSING *
95-S-7 MISSING *
95-S-8 MISSING *
95-S-9 MISSING *
95-S-10 MISSING *
95-S-11 LIQUID OXYGEN TANK BAY PLAN & SECTIONS
93-S-12 LIQUID OXYGEN TANK BAY SECTION & DETAILS
93-S-13 LIQUID OXYGEN TANK BAY FOUNDATION & WALL PLAN
95-S-14 MISSING *
93-S-15 NO. 2 DEVELOPED ELEVATIONS
* Drawing is thought to be missing, meaning that it is thought to be in the index, but unavailable. This drawing's existence is only suggested by another drawing with a higher number. E.g., If a drawing such as 92-S-3 exists, it is reasonable to infer that 92-S-1 and 92-S-2 also likely exist. It is possible however, that some drawings which are expected to exist may have been deleted from the drawing index, so there is no certainty that these drawings actually exist, and so these entries should only be considered as placeholders.